Main Menu; Instrumentation Setup (Torque); Figure 3-4 Main Menu - Magtrol DSP7000 User Manual

High speed programmable dynamometer controller dsp7000 series
Table of Contents

Advertisement

Chapter 3 – Installation/Configuration
3.1.2
M
M
ain
enu
When the DSP7000 is completely powered up and ready for use, the main menu will appear on the
display.
3.2

instrumentation setup (torque)

The DSP7000 has the ability to support a combination of up to two testing instruments with
independent or tandem configurations.
Note:
The setup of your unit will depend on which option you choose. The following sections will illustrate
and outline the hardware connection and software configurations needed to begin your testing, based
on your selection. For additional reference, see Appendix C: Front Panel/Display Menu Flow Charts.
Each channel of the DSP7000 can support the following dynamometers:
POWER
TORQUE
0.000 W
0.000 OZ.IN
OFF
BRAKE STATUS
SET POINT
Figure 3–4 Main Menu
In the TSC1 (Wb/Pb) and TSC2 (Wb/Pb) combination, the
instruments can be configured independently or as a tandem unit.
Magtrol Model DSP7000 Dynamometer Controller
SPEED
0
0000
SET POINT
TSC 1/TSC 2
HD
WB
PB
TM/TF
HD5
20
USER DISPLAY
0% 0% 0%
P
I
D