Speed Commands - Magtrol DSP7000 User Manual

High speed programmable dynamometer controller dsp7000 series
Table of Contents

Advertisement

Magtrol Model DSP7000 Dynamometer Controller
Command
Code
Channel 1
UI1,#
UR1,#
7.4.5
S
C
peeD
oMManDS
Command
Code
Channel 1
F1,xx.xx
Command
Code
Channel 2
UI2,#
Sets dynamometer torque
units to #.
UR2,#
Sets readout torque units to #. This command sets the torque
Command
Code
function
Channel 2
F2,xx.xx
Sets maximum speed to
xx.xx rpm.
CO,xx.xx
Sets maximum excited
speed of PB dynamometer.
79
Chapter 7 – Computer Controlled Operation
function
note: For Hp and watts
calculations to be correct, the
correct dynamometer torque
units must be specified.
Values for # are:
0 = oz.in.
1 = oz.ft.
2 = lb.in.
3 = lb.ft.
4 = g.cm.
5 = kg.cm.
6 = mN.m.
7 = cN.m.
8 = N.m.
Torque units default to 0 (oz.
in.) if out of range.
Programmed value # is not
saved at power down.
unit conversion for the torque
readout.
Values for # are
0 = oz.in.
1 = oz.ft.
2 = lb.in.
3 = lb.ft.
4 = g.cm.
5 = kg.cm.
6 = mN.m.
7 = cN.m.
8 = N.m.
Torque units default to 0 (oz.
in.) if out of range.
Programmed value # is not
saved at power down.
Sets a speed range for the
controller. Must be specified
before using the speed or ramp
mode.
Sets maximum excited speed
of PB dynamometer for clutch
deactivation on WB and
PB dynamometer tandem
application.
explanation
explanation

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents