Magtrol Model DSP6001 Dynamometer Controller
3.2.11
e
-C
DDy
Urrent
3.2.11.1
Hardware Connection
Torque/Speed
Conditioner
DES Power Supply
Figure 3–27 Eddy-Current Dynamometer with Powder Brake Dynamometer (Tandem Setup)
3.2.11.2
Software Configuration
1. Turn on the DSP6001 and proceed to the dynamometer configuration menu. See Section
3.2.1 – Dynamometer Configuration Menu.
2. Select TSC1 until WB is reached.
3. Select TSC2 until PB is reached.
4. Press SHIFT to get to the TSC1 Eddy-Current Setup Menu as seen below.
5. Press TORQUE UNITS button and use UP  and DOWN  buttons and Decrease/Increase
dial to set desired scale factor for TSC1.
6. Press SHIFT 2 times. The display should appear as shown in Figure 3–19 Nominal Speed
Setup Menu.
7. Press the AUX SETUP button and use UP  and DOWN  buttons and Decrease/Increase
dial to set desired nominal speed.
D
p
ynaMoMeter witH
Powder Brake
Dynamometer (PB)
TSC 401
Torque
Excitation
BRAKE
DSP6001
ACCESSORY
TORQUE–SPEED
Dynamometer
OUTPUT
CTRL OUT
Controller
BRAKE FUSE
(5×20mm): UL/CSA 1.25A 250V SB
IEC 1A 250V T
POWER
TORQUE
BRAKE STATUS
SET POINT
Figure 3–28 TSC1 Eddy-Current Setup Menu
Chapter 3 – Installation/Configuration
B
D
owDer
rake
ynaMoMeter
Eddy-Current Brake
Dynamometer (WB)
Clutch
(EK)
Speed
Transformer
Torque
Excitation
CAUTION: DOUBLE POLE FUSING
AUX / TSC2
SUPPLY 2
DYNAMOMETER / TSC1
GPIB/IEEE–488
SUPPLY 1
RS-232C
120V UL/CSA 800mA 250V SB
MAGTROL, INC. BUFFALO, NY
FUSE (5×20mm):
240V IEC 315mA 250V T
SPEED
SET POINT
33
(t
S
)
anDeM
etUp
TSC 401
Torque-Speed
Conditioner
DES Power Supply
PC
75VA 50/60Hz
M-TEST
EARTH
GROUND
GPIB
or
RS-232
STATUS
P
I
D