HART Menu Tree

Figure 3-1. HART Communicator Menu Tree
1. PROCESS
On-line Menu
VARIABLES
1. DEVICE SETUP
2. PV is
3. PV
4. PV AO
5. % RNGE
6. PV LRV
7. PV URV
2. DIAGNOSTICS
AND SERVICE
3. CONFIGURATION
4. REVIEW
Options listed in bold type indicate that a selection provides other options. For
ease of operation, changing calibration and setup, such as sensor type,
number of wires, and range values, can be completed in several locations.
1. TRANSMITTER VARS
2. PV is
3. PV Digital Reading
4. PV AO
5. PV% rnge
6. PV LRV
7. PV URV
8. PV Lower Sensor Limits
9. PV Upper Sensor Limits
10.PV Damping
1. Loop Test
2. Self test
1. TEST DEVICE
3. Master Reset
4. Status
2. CALIBRATION
1. SNSR 1 TRIM
3. Write Protect
2. D/A trim
3. Scaled D/A trim
1. VARIABLE
MAPPING
1. PV is
2. SV is
3. TV is
4. QV is
5. Variable re-map
2. SENSOR
1. SENSOR 1
CONFIGURATION
2. TERMINAL TEMP
1. PV RANGE
VALUES
3. DEVICE OUTPUT
CONFIGURATION
2. ALARM
SATURATION
3. HART OUTPUT
4. LCD METER
OPTIONS
1. Tag
2. Date
4. DEVICE
3. Descriptor
INFORMATION
4. Message
5. Final Assembly number
5. MEASUREMENT
1. 50/60 Hz Filter
FILTERING
2. Active Calibrator
3. Open Sensor Holdoff
4. Intermit Detect
1. Revision #s
5. Intermit Thresh
2. Sensor Review
3. Dev Outputs Review
4. Device Information
5. Measurement
Filtering
Models 644H and 644R
1. Snsr 1 Digital Reading
2. Terminal Digital Reading
1. Snsr 1 Input Trim
2. Snsr 1 Trim-Fact
3. Active Calibrator
1. Connections
2. SNSR 1 SETUP
3. CAL VANDUSEN
4. Sensor S/N
1. Terminal Units
2. Terminal Damp
3. Terminal LSL
4. Terminal USL
1. PV LRV
2. PV URV
3. PV Damping
4. PV Units
5. Apply Values
6. PV LSL
7. PV USL
8. PV Min. Span
1. AO Alarm Type
2. Low Alarm
3. High Alarm
4. Low Sat.
5. High Sat.
1. Poll Addr
2. Num Req Preams
3. Burst Mode
4. Burst Option
1. Meter Configuration
2. Meter Decimal Pt
These numbers are to
be entered by the user.
The review menu lists all of the
information stored in the Model 644. This
includes device information, measuring
element, output configuration, and
software revision
1. 2-wire Offset
2. Snsr 1 Units
3. Snsr 1 Damp
4. Snsr LSL
5. Snsr USL
1. R0
2. Alpha
3. Delta
4. Beta
When the hardware alarm
switches are changed, the
Model 275 should be power
cycled to see new readings.
3-3