Using The Autoconfiguration Adapter (Aca) - Hirschmann RS20 Reference Manual

Industrial ethernet (gigabit) switch
Hide thumbs Also See for RS20:
Table of Contents

Advertisement

Basic Settings
Reset the device to the state on delivery. After the next restart, the IP
address is also in the state on delivery.
1.6.5

Using the AutoConfiguration Adapter (ACA)

The ACAs are devices for saving the configuration data of a device. In the
case of a device failure, an ACA enables the configuration data to be
transferred easily by means of a substitute device of the same type.
Note: If you replace a device with DIP switches, please ensure that the DIP
switch settings are identical.
Storing the current configuration data in the ACA:
You have the option of transferring the current device configuration,
including the SNMP password, on the ACA and the flash memory in the
"Save" frame using the "to Switch / Save configuration" option.
Transferring the configuration data from the ACA:
When you restart with the ACA connected, the device adopts the
configuration data of the ACA and saves it permanently in the flash
memory. If the connected ACA does not contain any valid data, for
example, if the delivery state is unchanged, the device loads the data from
the flash memory.
Note: Before loading the configuration data from the ACA, the device
compares the password in the device with the password in the ACA
configuration data.
The device loads the configuration data if
the admin password matches or
RM Web L2E
Release 6.0 07/2010
1.6 Loading/Saving the Configuration
33

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rs40Ms20Ms30Rs30

Table of Contents