Switching

4.1 Switching Global

Variable
Meaning
MAC address
Display the MAC address of the device
(read only)
Aging Time (s) Enter the Aging Time in seconds for
dynamic MAC address entries.
In connection with the router redundancy,
select a time ≥ 30 s.
Flow control
Activate/deactivate the flow control
Note: When you are using a redundancy
function, you deactivate the flow control
on the participating ports. Default setting:
flow control deactivated globally and
activated on all ports.
If the flow control and the redundancy
function are active at the same time, there
is a risk of the redundancy failing.
Learning
Activate/deactivate the learning of MAC
addresses
source addresses.
Frame size
Set the maximum packet size (frame size)
in bytes.
Activate
Enable/disable whether the device
Address
detects whether it has repeatedly learned
Relearn
the same MAC source addresses at
Detection
different ports. This process very probably
indicates a loop situation in the network.
If the device detects this process, it
creates an entry in the log file and sends
an alarm (trap).
Table 28: Switching:Global dialog
76
4.1 Switching Global
Possible Values
15-3.825
30
On, Off
Off
On, Off
On
1522, 1632
1522
On, Off
Off
Release 6.0 07/2010