Time
3.2.1
PTP Global (MS20/MS30, PowerMICE,
MACH 104, MACH 1040)
The table below helps you to select the PTP version and the PTP mode.
Version
Mode
Version 1
v1-simple-mode
v1-boundary-clock
Version 2
v2-simple-mode
v2-boundary-clock-
onestep
v2-boundary-clock-
twostep
v2-transparent-clock
Table 12: Selecting the PTP version and the PTP mode
The PTP modes
- v1-boundary-clock,
- v2-boundary-clock-onestep,
- v2-boundary-clock-twostep and
- v2-transparent-clock
enable you to optimize the accuracy of the time.
You use these dialogs here
Version 1
Version 2 (Boundary Clock, BC)
Version 2 Transparent Clock, (TC)
The PTP modes
- v1-simple-mode and
- v2-simple-mode
allow you to use the plug-and-play start-up.
60
Reference clock
Device with
used
timestamp
Version 1
No
Version 1
Yes
Version 2
No
Version 2
Yes
Version 2
Yes
Version 2
Yes
3.2 PTP (IEEE 1588)
PTP messages
Process
Process
Process
Forward
RM Web
Release 6.0 07/2010