Canceling A Configuration Change - Hirschmann RS20 Reference Manual

Industrial ethernet (gigabit) switch
Hide thumbs Also See for RS20:
Table of Contents

Advertisement

Basic Settings
there is no password saved locally or
the local password is the original default password or
no configuration is saved locally.
Status
Meaning
notPresent
No ACA present
ok
The configuration data from the ACA and the device
match.
removed
The ACA was removed after booting.
notInSync
- The configuration data of the ACA and the device do
not match or only one file exists
or
- no configuration file is present on the ACA or on the
device
outOfMemory
The local configuration data is too extensive to be
stored on the ACA.
wrongMachine
The configuration data in the ACA originates from a
different device type and cannot be read or converted.
checksumErr
The configuration data is damaged.
Table 3: ACA Status
a. In these cases, the ACA status is identical to the status "ACA not in
sync", which sends "Not OK" to the signal contacts, and the device
status.
b. In this case, the ACA status ("notInSync") deviates from the status
"ACA not in sync", which sends "OK" to the signal contacts, and the
device status.
1.6.6

Canceling a configuration change

Function
If the function is activated and the connection to the device is interrupted
for longer than the time specified in the field "Period to undo while
connection is lost [s]", the device then loads the last configuration saved.
Activate the function before you configure the device so that you will
then be reconnected if an incorrect configuration interrupts your
connection to the device.
34
b
.
1.6 Loading/Saving the Configuration
a
,
RM Web
Release 6.0 07/2010

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rs40Ms20Ms30Rs30