Time - Hirschmann RS20 Reference Manual

Industrial ethernet (gigabit) switch
Hide thumbs Also See for RS20:
Table of Contents

Advertisement

Time

3 Time
With this dialog you can enter time-related settings independently of the time
synchronization protocol selected.
The "IEEE/SNTP time" displays the time with reference to Universal Time
Coordinated (UTC).
The time displayed is the same worldwide. Local time differences are not
taken into account.
The "System time" uses the "IEEE 1588 / SNTP time", allowing for the
local time difference from "IEEE 1588 / SNTP time".
"System time" = "IEEE 1588 / SNTP time" + "Local offset".
"Time source" displays the source of the following time data. The device
automatically selects the source with the greatest accuracy.
Possible sources are: local and sntp. The source is initially local. If
SNTP is activated and if the device receives a valid SNTP packet, the
device sets its time source to sntp.
With "Set time from PC", the device takes the PC time as the system time
and calculates the IEEE 1588 / SNTP time using the local time difference.
"IEEE 1588 / SNTP time" = "System time" - "Local offset"
The "Local Offset" is for displaying/entering the time difference between
the local time and the "IEEE 1588 / SNTP time".
With "Set offset from PC", the agent determines the time zone on your PC
and uses it to calculate the local time difference.
Note: When setting the time in zones with summer and winter times, make
an adjustment for the local offset, if applicable. The device can also get the
SNTP server IP address and the local offset from a DHCP server.
RM Web L2E
Release 6.0 07/2010
2.5 Port Security
53

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rs40Ms20Ms30Rs30

Table of Contents