Ag7 Audio Generator Module Remote Commands; Output Commands - Tektronix TG8000 Programmer's Manual

Multiformat test signal generator
Hide thumbs Also See for TG8000:
Table of Contents

Advertisement

AG7 Audio Generator module remote commands

OUTPUT commands

Command tree
Command description
Draft
TG8000 Multiformat Test Signal Generator Programmer Manual
This section describes the command sets used for the AG7 Audio Generator
module remote operation. The commands for the module are divided into the
following groups:
OUTPUT commands
SENSE commands
Use these commands to set the parameters for each audio channel, the audio data
resolution, and the synchronization state relative to the frame reset signals.
:OUTPut
:AUDio
:CHANnel<n>
:AMPLitude
:FREQuency
:CLICk
:NBITs
:SYNChronized
:OUTPut:AUDio:CHANnel<n>:AMPLitude <numeric_value>
Sets the amplitude of a specific audio channel. The numeric value can
range from -60 dBFS to 0 dBFS in 1 dBFS steps. The <n> in the command
represents the channel number. You can use any channel number from 1
through 8.
:OUTPut:AUDio:CHANnel<n>:AMPLitude?
Returns the amplitude of a specific audio channel. The <n> in the command
represents the channel number. You can use any channel number from 1
through 8.
:OUTPut:AUDio:CHANnel<n>:FREQuency <numeric_value>
Sets the frequency of a specific audio channel. The unit is Hertz. The choices
are 0, 50, 100, 150, 200, 250, 300, 400, 500, 600, 750, 800, 1000, 1200, 1500,
1600, 2000, 2400, 3000, 3200, 4000, 4800, 5000, 6000, 8000, 9600, 10000,
12000, 15000, 16000, and 20000. The <n> in the command represents the
channel number. You can use any channel number from 1 through 8.
AG7 Audio Generator module remote commands
<numeric_value>
<numeric_value>
0 | 1 | 2 | 3 | 4
FREErun|FRAME_ONE|FRAME_TWO
29