■ Ground connection

The transceiver and antenna tuner MUST have an
adequate ground connection. Otherwise, the overall
efficiency of the transceiver and antenna tuner instal-
lation will be reduced. Electrolysis, electrical shocks
and interference from other equipment could also
occur.
For best results, use the heaviest gauge wire or strap
available and make the connection as short as possi-
ble. Ground the transceiver and antenna tuner to one
ground point, otherwise voltage differences between
2 ground points may cause electrolysis.
CAUTION: The IC-M700PRO has a negative
ground. NEVER connect the IC-M700PRO to a
"positive ground system," otherwise the transceiver
will not function.
Ground system example
Transceiver
Copper pipe

■ Power source

The transceiver requires regulated DC power of
13.6 V and at least 30 A. There are 3 ways to sup-
ply power:
• A direct connection to a 12 V battery in your ship,
through the supplied DC power cable.
CAUTION: The supplied DC power cable MUST be
used to provide power to the transceiver. AVOID ex-
ceeding the 3 m (10 ft) length of the DC power cable.
If it is necessary to make a run of over 3 m (10 ft),
use a #6 or similar gauge wire instead of the sup-
plied DC power cable, for a maximum run of 6 m
(20 ft).
Metal object
Copper screen
CONNECTIONS AND INSTALLATION
Good ground points
• Ship's ground terminal
• External ground plate
• External copper screen
Acceptable ground points
• Stainless steel tuna tower
• Stainless steel stanchion
• Through mast
• Through hull
• Metal water tank
Undesirable ground points
(these points may cause electrolysis)
• Engine block
• Keel bolt
Unusable ground points
(these connections may cause an explosion or elec-
trical shock)
• Gas or electrical pipe
• Fuel tank
• Oil-catch pan
Optional AT-130
DC power cable connection
black
12 V
battery
Supplied
DC power cable
6
NOTE: Use terminals for
the cable connection.
Crimp
red
or
Solder
18