Cooling powers to be dissipated
The values specified in the table refer to a cooling medium temperature of 30 °C and maxi-
mum speed in S1 duty.
Table 1-11
1FT6 Synchronous Motors
Configuration Manual, (PFT6), 10.2005 Edition, 6SN1197-0AD02-0BP1
Cooling powers to be dissipated
Motor type
1FT6062–6WF7
1FT6062–6WH7
1FT6062–6WK7
1FT6064–6WF7
1FT6064–6WH7
1FT6064–6WK7
1FT6084–8WF7
1FT6084–8WH7
1FT6084–8WK7
1FT6086–8WF7
1FT6086–8WH7
1FT6086–8WK7
1FT6105–8WC7
1FT6105–8WF7
1FT6108–8WB7
1FT6108–8WC7
1FT6108–8WF7
1FT6132–6WB7
1FT6132–6WD7
1FT6134–6WB7
1FT6134–6WD7
1FT6136–6WB7
1FT6136–6WD7
1FT6138–6WB7
1FT6138–6WD7
1FT6163–8WB7
1FT6163–8WD7
1FT6168–8WB7
Motor Description
To be dissipated
cooling power [W]
600
650
700
800
850
900
1500
1900
2200
1800
2000
2400
2000
2100
1900
2100
2300
2600
2700
2700
3100
3300
3600
3600
4000
4500
6000
7500
Cooling