Electrical Connections
Connection through a terminal box
2.2
Connection through a terminal box
•
The terminal assignment in the terminal box must be implemented according to the dia-
gram.
•
The protective conductor must be connected.
•
Cable lugs acc. to DIN 46234 must be used.
•
Connect up an optional brake (refer to the diagram).
Notice
Motors with a rated power of more than 100 kW must be grounded using the additional
M12 grounding stud provided at the NDE bearing endshield.
Fig. 2-2
Table 2-1
2-2
Terminal assignment in the terminal boxes
Description of the diagram
No.
Description
1
M5 connecting studs
2
M10 connecting studs
3
M4 grounding stud
4
M6 grounding stud
No.
5
6
BD1+ / BD2-
Configuration Manual, (PFT6), 10.2005 Edition, 6SN1197-0AD02-0BP1
Description
M10 grounding studs
M4 connecting studs
Brake connection
1FT6 Synchronous Motors