Table 1-6
Resistor braking for the 1FT6 series, water cooling
Braking
resistor
Motor type
external
R
1FT6163-8WD7
1FT6168-8WB7
1)
When utilized acc. to M0 (100 K), a series braking resistor must be used in order to prevent partial de-magnetiza-
tion.
When utilized according to M0 (60 K), the additional braking resistor is not required.
2)
It is absolutely prohibited to short-circuit the winding when using smaller supplementary resistors than those speci-
fied. When braking from the rated speed, the resistors listed prevent partial de-magnetization of the rotor.
1FT6 Synchronous Motors
Configuration Manual, (PFT6), 10.2005 Edition, 6SN1197-0AD02-0BP1
Average braking torque
M
br rms
without
external
[Ω]
braking resis-
opt
tor
2)
0.25
2)
0.27
[Nm]
Max.
braking
with
torque
external
M
braking resis-
br max
tor
380
530
Motor Description
Armature short-circuit braking
RMS braking current
I
br rms
without
external
[Nm]
braking resis-
tor
490
680
[A]
Max.
braking
torque
M
[Nm]
br max
390
340