Technical Data
Power supply:
Current:
Fuse type
Maximum rated current:
Protection type:
Ambient temperature:
Storage temperature:
Relative humidity:
Flow meter input:
Measuring range:
Temperature measurement
resolution:
Temperature measuring accuracy
when working with sensors T1001
and T1301:
Connectors:
Display:
Dimensions:
Weight:
Sensor specification
Temperature Resistance
-40
-30
-20
-10
0
10
20
40
[°C]
[Ω]
842.1
881.7
921.3
960.7
1000.0
1039.0
1077.9
230V, 50Hz
I < 0.02A
WTA-F 2A
P1
P2
P3
IP20
0..55°C
0..55°C
5 – 80% without vapour condensation
Frequency max. 5Hz
Pulse time low min. 90ms,
high min. 90ms.
T1,
T2, T3, T4
T4 in variants no. 11 and
12
-40..0 °C
0..+110 °C
+110..+200 °C
Screw terminals 1x1.5mm²
LCD graphic display, backlit
104x155x50mm
0.45kg
Temperature Resistance
[°C]
30
40
50
60
70
80
90
S
OLAR
0.6A
2(0.6)A
2(0.6)A
-40.. +200°C
-9..+99°C
-40..+200
0,1°C
±2°C
±1°C
±2°C
[Ω]
1116.7
1155.4
1194.0
1232.4
1270.7
1308.9
1347.0
C
951 model u7.x, Rev. 1
OMP
Need help?
Do you have a question about the SOLARCOMP 951 and is the answer not in the manual?