D. SERVICE SETTINGS
20.SOLAR FLUID TYPE
1
MIN 0
D. SERVICE SETTINGS
21.NOMINAL FLOW
(pump output)
8.0
l/min
MIN 0.0
MAX 50.0
D. SERVICE SETTINGS
22.FLOW METER
(liter/pulse)
1.0
MIN 0.0
MAX 50.0
D. SERVICE SETTINGS
23.LADDOMAT NOMINAL
FLOW (pump output)
8.0
l/min
MIN 0.0
MAX 50.0
D. SERVICE SETTINGS
24. T1 SENSOR
ADJUSTMENT
0.0K
MIN -10.0
MAX 10.0
D. SERVICE SETTINGS
25. T2 SENSOR
ADJUSTMENT
0.0K
MIN -10.0
MAX 10.0
S
C
951 model u7.x, Rev. 1
OLAR
OMP
TYPE OF SOLAR THERMAL FLUID
0
Water
1
ERGOLID EKO -15°C
2
ERGOLID EKO -20°C
MAX 22
3
ERGOLID EKO -25°C
4
ERGOLID EKO -35°C
5
Transtherm N -15°C
6
Transtherm N -20°C
7
Transtherm N -25°C
8
Transtherm N -35°C
9
Transtherm EKO -15°C
10 Transtherm EKO -20°C
11
Transtherm EKO -25°C
Default setting: 1
NOMINAL FLOW – solar pump output. The value displayed by
the flow meter (rotameter) of the solar unit when the pump
operates at full speed.
Default setting: 8.0 l/min
FLOW METER
Flow meter pulser constant.
This parameter is valid for heat meter 3 or 4.
Default setting: 1.0 l/pulse
LADDOMAT NOMINAL FLOW
Only for variant no. 10.
This value is used to count the energy obtained from the
boiler. Enter the actual flow through the boiler.
Default setting 8.0 l/min.
T1 sensor reading adjustment.
Default setting: 0.0K
T2 sensor reading adjustment.
Default setting: 0.0K
12 Transtherm EKO -35°C
13 Termsol EKO concentrate
14 Termsol EKO -15°C
15 Termsol EKO -20°C
16 Termsol EKO -25°C
17 Termsol EKO -35°C
18 Termsol EKO-PRO -35°C
19 Immericol [BORIGHICOL PG
-35°C]
20 Immericol Alu
[BORIGHICOL PG -30°C ALU]
21 e'SOL – 29 °C
22 LAJT SOL – 29 °C
17