Dell S5000 Deployment/Configuration Manual page 77

Deployment of a converged infrastructure with fcoe
Hide thumbs Also See for S5000:
Table of Contents

Advertisement

Dell Networking S5000: Deployment of a Converged Infrastructure with FCoE
Figure 96: Dell QLogic QLE8262 adapter propertise displaying the created NIC team
The NIC team will now show in Windows as a new virtual adapter as shown in Figure 97 and Figure 98.
Figure 97: Virtual adapter network connection as seen in Windows
Figure 98: NIC team virtual adapter as seen in 'Device Manager' in Windows
As far as the network configuration for the LAN, since 'Failsafe Team' is being utilized, there is no
special configuration that needs to be done on the S5000 switches. We can simply have one link
going to each S5000 switch with one port in 'active' mode and the other in 'standby' mode.
In our examples in sections A and B, we had tagged the LAN traffic on VLAN 5. We can easily tag the
NIC team with VLAN 5 by right clicking the VLAN name and entering the respective VLAN as shown
below.
77
Deployment of a Converged Infrastructure with FCoE
Deployment/Configuration Guide

Advertisement

Table of Contents
loading

Table of Contents