Dell Networking S5000: Deployment of a Converged Infrastructure with FCoE
Figure 28: Zoning for fabric B FC switch
> zonecreate
financeServer1_p2_test,"50:00:d3:10:00:ed:b2:3c;50:00:d3:10:00:ed:b2:42;50:00:d3:10:00:ed:b2:3a;
50:00:d3:10:00:ed:b2:40;20:01:00:0e:1e:0f:2d:8f "
> cfgcreate zoneCfg_test,"financeServer1_p2_test"
> cfgenable zoneCfg_test
> cfgsave
Figure 29: Output of the 'zoneshow' command on the fabric A FC switch
You can see that our zoning configuration matches what is displayed in Figure 27.
If we look at the details of what's connected to port 4 of the fabric A FC switch, we see the WWPNs of
both the Dell S5000 switch and the Dell QLogic CNA.