Dell S5000 Deployment/Configuration Manual page 53

Deployment of a converged infrastructure with fcoe
Hide thumbs Also See for S5000:
Table of Contents

Advertisement

Dell Networking S5000: Deployment of a Converged Infrastructure with FCoE
the zoning configuration.
Figure 55: Zoning for fabric A FC switch
> zonecreate
financeServer1_p1_test,"20:14:90:b1:1c:04:a4:84;20:15:90:b1:1c:04:a4:84;20:34:90:b1:1c:04:a4:84;
20:35:90:b1:1c:04:a4:84;20:01:00:0e:1e:0f:2d:8e"
> cfgcreate zoneCfg_test,"financeServer1_p1_test"
> cfgenable zoneCfg_test
> cfgsave
Figure 56: Zoning for fabric B FC switch
> zonecreate
financeServer1_p2_test,"20:24:90:b1:1c:04:a4:84;20:25:90:b1:1c:04:a4:84;20:44:90:b1:1c:04:a4:84;
20:45:90:b1:1c:04:a4:84;20:01:00:0e:1e:0f:2d:8f"
> cfgcreate zoneCfg_test,"financeServer1_p2_test"
> cfgenable zoneCfg_test
> cfgsave
Figure 57: Output of the 'zoneshow' command on the fabric A FC switch
You can see that our zoning configuration matches what is displayed in Figure 55.
53
Deployment of a Converged Infrastructure with FCoE
Deployment/Configuration Guide

Advertisement