Dell S5000 Deployment/Configuration Manual page 62

Deployment of a converged infrastructure with fcoe
Hide thumbs Also See for S5000:
Table of Contents

Advertisement

Dell Networking S5000: Deployment of a Converged Infrastructure with FCoE
Figure 69: Fabric A Dell MXL (FSB) configuration
> enable
> config terminal
> dcb enable
> feature fip-snooping
> service-class dynamic dot1p
> interface range fortyGigE 0/33 - 37
> port-channel-protocol lacp
> port-channel 12 mode active
> exit
> protocol lldp
> no advertise dcbx-tlv ets-reco
> dcbx port-role auto-upstream
> no shut
> exit
> interface port-channel 12
> portmode hybrid
> switchport
> fip-snooping port-mode fcf
> no shutdown
> exit
> interface tengigabitethernet 0/9
> portmode hybrid
> switchport
> protocol lldp
> dcbx port-role auto-downstream
> no shut
> exit
> interface vlan 5
> tagged tengigabitethernet 0/9
> tagged port-channel 12
> exit
> interface vlan 1002
> tagged tengigabitethernet 0/9
> tagged port-channel 12
> fip-snooping fc-map 0efc01
> fip-snooping enable
> exit
> uplink-state-group 1
> downstream TenGigabitEthernet 0/12
> upstream Port-channel 12
> downstream auto-recover
> end
> write
62