Firmware Upgrade - ABB CDD Product Manual

Concentrator data device
Table of Contents

Advertisement

2. Direct to the computer using an Ethernet cable
This type of connection should only be used for configuration of the system to access the CDD internal
configuration pages (local web server)
If the computer is directly connected to the CDD without a router, and if the computer is set for
an automatic IP address, it is necessary to change the Network settings on the computer fol-
lowing the procedure below:
Click on the internet icon in the computer system tray and open the Network and Sharing
Center
Click Local Area Connection (LAN)
Click Properties
Click Internet Protocol Version 4 (TCP/IPv4)
Click Get the following IP address and type a different IP Gateway address from that of the
CDD (e.g. if the CDD IP gateway address is 192.168.0.100, type 192.168.0.101) and click
OK
The IP Gateway address of the CDD is shown on the display by pressing any button and
scrolling DOWN the basic list.
Once these parameters are changed, input the IP Gateway address of the (CDD) in the
address bar of the Internet Browser to proceed with the acquisition of the plant.
To reset the wireless connection on the computer, follow the steps in reverse order.
F
irmware upgrade
It is recommended to upgrade the CDD firmware when connection to the internet is complete.
The firmware upgrade can be done in three different ways:
1. Firmware updgrade using the CDD display menu.
2. Firmware upgrade using the CDD web user interface (with either Ethernet or wireless
connection).
See System monitoring, part 6, for instructions to upgrade using method 1 or 2.
2. CDD Firmware update using Aurora Vision
A firmware update from Aurora Vision will be completed automatically following the procedure for self-
registration found in part 6.