E
thernet connection to the internet
WLess connectivity is enabled by default and will need to be disabled before connecting the Ethernet cable
using the following procedure:
Press any button on the CDD from the GENERAL INFORMATION display to enter the BASIC menus.
Scroll to WLess Enabled and press ENTER
Use the UP and DOWN keys to change to NO and press ENTER.
Once the wireless is disabled the CHANGE SETTINGS menu will be used to modify the Network settings.
Press and hold the UP and DOWN buttons on the CDD display at the same time until the Set Password
screen is displayed.
Using the UP or DOWN buttons, enter the password of 0010 by scrolling the
list of characters.
Press ENTER to confirm each character selected; press ESC to cancel the last
character input.
When the password has been entered, scroll to the CHANGE SETTINGS
menu and press ENTER.
Scroll to Network and press ENTER to select.
Scroll to select Select Network, WLess and press ENTER.
Scroll to Ethernet and press ENTER to select.
The CDD will automatically restart to reset the connection settings.
Connect the Ethernet cable if not already connected. Two possibilities for cabled
connection of the CDD to the computer are shown below.
The Ethernet port is located on the lower side of the CDD.
For either connection, be careful not to put the Ethernet cable in the RJ45 connector
for RS-485 serial communication.
1. Through a router using an Ethernet cable
This type of connection can be used both during configuration of the system to access the CDD internal
configuration pages (local web server) and for data transmission to the web portal in order to monitor the
system.
Router / Switch
CDD
Ethernet cable
- 19 -
4 - Connect and configure the CDD
WLess enabled
NO
Set Password
XXXX
Change
Settings
Network
Select Network
WLess
Select Network
Ethernet >
>
>
>
>