Removing the External Fan
1.
Remove the front cover.
2.
Unplug the fan connector (CN7).
Figure 20
A – Fan
B – Fan relay cable
<1> The external fan is installed outside of the waterproof/dust-proof enclosure.
Figure 20 Replacing the External Fan (Removing the External Fan in 2A0069)
3.
Remove the screws to take the fan guard out of the drive. Push the rubber bushing
out of conduit hole and take the internal fan out of the drive.
Figure 21
Rubber bushing
Push the rubber bushing
out of the wiring holes
YASKAWA ELECTRIC TOBP C710606 35D YASKAWA AC Drive - V1000 NEMA Type 4X/IP66 Installation Manual
A
D
<1>
Figure 21 Replacing the External Fan
9 Drive Cooling Fans
C
B
C – Fan connector (CN7)
D – Rubber bushing
Label
Bolt 7 mm