JLG G5-18A Service Manual page 30

Hide thumbs Also See for G5-18A:
Table of Contents

Advertisement

General Information and Specifications
2.7.2
Metric Fastener Torque Chart (Continued)
Size
Pitch
3
0.5
3.5
0.6
4
0.7
5
0.8
6
1
7
1
8
1.25
10
1.5
12
1.75
14
2
16
2
18
2.5
20
2.5
22
2.5
24
3
27
3
30
3.5
33
3.5
36
4
42
4.5
NOTES:
1. THESE TORQUE VALUES DO NOT APPLY TO CADMIUM PLATED FASTENERS
2. ALL TORQUE VALUES ARE STATIC TORQUE MEASURED PER STANDARD AUDIT METHODS TOLERANCE = ±10%
3. * ASSEMBLY USES HARDENED WASHER
4. CLAMP LOAD LISTED FOR SHCS IS SAME AS GRADE 8 OR CLASS 10.9 AND DOES NOT REPRESENT FULL STRENGTH CAPABILITY OF SHCS.
IF HIGHER LOAD IS REQUIRED, ADDITIONAL TESTING IS REQUIRED.
2-18
Values for Magni Coated Fasteners (Ref 4150701)*
CLASS 10.9 METRIC (HEX HEAD) BOLTS CLASS 10 METRIC NUTS,
CLASS 12.9 SOCKET HEAD CAP SCREWS M6 AND ABOVE*
Clamp Load See
Tensile Stress Area
Note 4
Sq mm
KN
5.03
3.13
6.78
4.22
8.78
5.47
14.20
8.85
20.10
12.5
28.90
18.0
36.60
22.8
58.00
36.1
84.30
52.5
115
71.6
157
97.8
192
119.5
245
152.5
303
189.0
353
222.0
459
286.0
561
349.5
694
432.5
817
509.0
1120
698.0
Torque
(Dry or Loctite® 263
K=0.17
Vibra-TITE
[N.m]
13
21
31
61
105
170
265
365
520
705
905
1315
1780
2425
3115
4985
Torque
(Lub or Loctite®
(Loctite® 262
242
or 271
or
Vibra-TITE
TM
111 or 140)
K=0.18
[N.m]
12
20
29
58
100
160
250
345
490
665
850
1235
1680
2285
2930
4690
5000059K
Torque
™ or
131)
K=0.15
[N.m]
11
19
27
55
95
150
235
325
460
625
800
1160
1575
2140
2750
4395
G5-18A, 2505

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

2505