Cleaning And Maintenance; Bvi 9400; Regular Inspections And Maintenance - Verathon BladderScan BVI 9400 User Manual

Bladder volume instrument
Hide thumbs Also See for BladderScan BVI 9400:
Table of Contents

Advertisement

BladderScan

BVI 9400

®

Cleaning and Maintenance

Cleaning and Disinfecting the BladderScan
To Clean and disinfect the BladderScan
1.
Use a soft cloth dampened with isopropyl alcohol (or an appropriate hospital
cleaning agent) to wipe the Probe until it is thoroughly cleaned.
2.
If you use a detergent solution to clean the instrument, remove all residual
detergent. Dry the instrument with a clean, soft cloth.
3.
If the instrument needs to be disinfected, dampen a soft cloth in any glutaraldehyde-
based hospital disinfectant solution such as Cidex
Sterilization Products, or Sporocidin
instrument with a dampened cloth.
4.
To remove all traces of disinfectant solution and wipe the instrument with a clean
soft cloth dampened in sterile water or cleaning solution. Verathon
wiping the device three separate times to remove all residual disinfectant.
5.
Thoroughly dry the instrument with a clean, soft cloth before using.
IMPORTANT! Failure to heed the following warnings may cause device damage not
covered by the BladderScan
Do not immerse the instrument in disinfectant solution.
Do not use CidexPlus
plastic enclosure.
Do not subject any part of the instrument to steam sterilization or ethylene
oxide sterilization.
Changing gel pads between patients is strongly recommended.

Regular Inspections and Maintenance

Verathon Medical
BladderScan
inspection and testing of the instrument to ensure accurate performance in clinical use.
For more information, please contact your authorized BladderScan
local BladderScan
1.800.331.2313 (North America only International customers, please refer to the contact
information on page 66).
NOTE:
ScanPoint
accessing their ScanPoint
please refer to the ScanPoint
User's Manual
BVI 9400 warranty.
®
to disinfect the instrument. CidexPlus will damage the
®
recommends that the BVI 9400 be certified by an authorized
®
Service Center once a year. Certification service includes comprehensive
®
distributor, or Verathon Medical
®
Online customers can maintain device certification via the Internet by
®
account. For more information about using ScanPoint
®
with QuickPrint User's Manual.
®
BVI 9400
®
BVI 9400:
®
or Cidex 7
®
from Sporocidin International. Wipe the
®
Customer Care Department at
®
Cleaning and Maintenance
from Advanced
®
recommends
®
Service Center, your
®
Online,
®
page 53

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents