Samsung RVMC060GDM0 Technical Manual page 181

Dv m air conditioner
Table of Contents

Advertisement

Item
Code
-
Motor output
Compressor
-
Compressor safety OLP
CCH
Crank case heater
Fan motor
Motor
Safety thermostat
Safety
devices
HPS
High pressure switch
LPS
Low pressure switch
HPSO
High pressure sensor
LPSO
Low pressure sensor
DTS
Thermistor (discharge)
CMS
Thermistor (condenser center)
COS
Thermistor (condenser outlet)
Temperature
OATS
Thermistor (outdoor temperature)
sensor
SUC.S
Suction sensor
OIL.S
Oil sensor
FDTS
Thermistor (fixed discharge)
Solenoid valve
PWM
(for compressor operation)
Solenoid valve
HGBV
(for bypass of high temperature gas)
LBV
Solenoid valve (liquid injection)
Functional
VBV
Solenoid valve (for exhaust air)
parts
BV1
Solenoid valve (for capacity control)
BV2
Solenoid valve (for capacity control)
4-W/V
4-way valve
C/V
Check valve
EEV
Electronic expansion valve (for heating)
Name
MUF7201F1
ZRD72KC-TF7
5.5kW
open temp.
155°C
trip current
70A
90W
model
OSM1076SRC
output
106W + 106W
on
150°C
off
100°C
OFF : 1.2(±0.2)kg/cm
ON : 2.2(±0.2)kg/cm
-
-
103AT (25°C=10kΩ)
-
-
-
-
-
-
-
-
Ι Λ
9
RVMC070FAM0
RVMC100GAM0
ZRD72KC-TF5
ZRDT14MC-TFD
5.5kW
4.2kW + 4.2kW
175°C
120°C/145°C
110A
60A/48A
90W
90W
OSM1076SRC
OSM4506SRC
106W + 106W
450W
150°C
150°C
100°C
100°C
OFF : 30(±1)kg/cm
2
ON : 22(±1)kg/cm
2
2
-
2
-
PS8030A (NH4-H) (0~30kg/cm
-
PS8030A (NH4-L) (0~10kg/cm
Model : 0166-01, Rt=150°C, 25°C=86Ω
-
103AT (25°C=10kΩ)
103AT (25°C=10kΩ)
-
-
-
-
-
204CTB (25°C=200kΩ)
Coil : Copeland (Part # 023-0028-03)
Body : EPV-1530D
Coil : Siginomiya
Body : NEV-603D
Coil : Siginomiya
Body : NEV-202D
-
-
-
-
-
-
-
-
-
-
RVMC100FAM0
ZRDU13MC-TF5
5.5kW + 4.3kW
175°C/160°C
110A/80A
90W
OSM4508SRC
450W
150°C
100°C
-
)
2
2
)
-
-
-
-
-
-
-
-