F. Remove distribution tubes.
Distribution tube thumbscrews are retained to
prevent loss. Loosen thumbscrews but do not pull
thumbscrews out of distribution tube.
Loosen the two outer screws and pull forward on
the distribution tube to release from slip joint.
Disassemble distribution tube by loosening the two
(2) middle thumbscrews and dividing the
distribution tube into two pieces.
NOTE: Each evaporator has a distribution tube that
must be removed - total of four distribution tubes.
G. Remove ice dampers.
Grasp ice damper and apply pressure toward the
back mounting bracket.
Apply pressure to the front mounting bracket with
thumb.
Pull ice damper downward when the front ice
damper pin disengages.
NOTE: Each evaporator has an ice damper that must
be removed - total of four ice dampers.
H. Remove the water pump assembly.
Disconnect the vinyl distribution tube from both
water pumps.
Disconnect the water pump and water level probe
electrical connections.
After the wires are disconnected remove the two
thumbscrews and lift the water pump assembly out
of the ice machine.
Remove the thumbscrews securing the water
pumps (2 each pump) and remove water pumps.
Do not immerse the water pump motor in cleaner
or sanitizer solutions.
Remove the water level probe from the assembly
housing.
I. Remove the water trough.
Pull forward on the water trough to remove.
NOTE: Proceed to page 49, Step 7.