Manitowoc SD0302A Technician's Handbook page 217

S series; s300 series; s420 series; s450 series; s500 series; s850 series; s1000 series; s1200 series; s1400w series; s1400a series; s1400n series; s1800w series; s1800a series; s1800n series
Hide thumbs Also See for SD0302A:
Table of Contents

Advertisement

Downloaded from
www.Manualslib.com
S600N
All Remote Air-Cooled Condenser Models
Characteristics may vary depending on operating conditions.
CYCLE TIMES
Freeze Time + Harvest Time = Total Cycle Time
Air Temp.
Entering
Condenser
°F/°C
7.9-9.4
-20/-29 to 70/21
80/27
8.1-9.5
90/32
8.8-10.3
100/38
9.7-11.4
110/43
1 Times in minutes
24 HOUR ICE PRODUCTION
Air Temp. Entering
Condenser
°F/°C
-20/-29 to 70/21
80/27
90/32
100/38
110/43
1 Based on average ice slab weight of 4.12 - 4.75 lb
2 Ratings with JC0895 condenser dice or half dice cubes
OPERATING PRESSURES
Freeze Cycle
Air Temp.
Entering
Discharge
Condenser
Pressure
°F/°C
PSIG
-20/-29 to
210-240
50/10
225-250
70/21
245-275
80/27
245-285
90/32
260-315
100/38
290-365
110/43
1 Suction pressure drops gradually throughout the freeze cycle
Part Number 80-1479-3 7/10
manuals search engine
Freeze Time
Water Temperature °F/°C
50/10
70/21
8.8-10.3
7.9-94
8.9-10.5-
8.9-10.5
9.7-11.4
10.4-12.2
10.6-12.5
Water Temperature °F/°C
50/10
70/21
630
630
620
580
530
Suction
Discharge
Pressure
Pressure
PSIG
PSIG
40-29
130-190
50-30
130-200
52-31
130-200
52-32
135-200
55-32
140-200
60-34
170-200
Harvest
1
Time
90/32
9.3-10.9
9.5-11.2
9.7-11.4
1-2.5
11.4-13.4
12
90/32
580
550
570
530
570
540
530
500
490
460
Harvest Cycle
Suction
Pressure
1
PSIG
62-80
75-95
75-100
80-100
80-100
85-100
217

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents