Operational Analysis
Freeze Cycle
Discharge Pressure
_____
______
1 minute
Middle
Freeze Cycle
Suction Pressure
_____
______
1 minute
Middle
Evaporator Outlet
Temperature Comparison
Attach and insulate temperature
probes between evaporator outlet
and 90° elbow
Downloaded from
www.Manualslib.com
S MODELS FOUR EXPANSION VALVES
1
If discharge pressure is High or Low refer to freeze cycle high or low discharge pressure problem checklist
_____
page 112 and eliminate problems and/or components not listed on this table before proceeding.
End
If suction pressure is High or Low refer to freeze cycle high or low suction pressure problem checklist
page 115 and eliminate problems and/or components not listed on this table before proceeding.
_____
Suction pressure is
End
High
Evaporator outlet
temperatures are
within 10°F of
each other
manuals search engine
2
3
Suction pressure
Suction pressure
is
is
Normal or Low
Normal or High
Evaporator outlet
temperatures are
Evaporator outlet
NOT within
temperatures are
10°F of each
other
NOT within
or
10°F of each
other
Within 10°F of
each other and
above 32°F
4
Suction pressure is
Suction pressure is
High
High
Evaporator outlet
Evaporator outlet
temperatures are
temperatures are
within 10°F of
within 10°F of
each other
each other