Downloaded from
www.Manualslib.com
S1400/S1600/S1800 -
Self-Contained - 1 Phase
L1
(89)
(55)
HIGH PRESSURE
CUTOUT
(88)
(42)
ICE THICKNESS
PROBE
WATER LEVEL
PROBE
CONTACTOR
*OVERLOAD
CONTACTS
(BLACK)
L1
(51)
(85)
Part Number 80-1479-3 7/10
manuals search engine
(21)
(20)
(61)
(77)
CONTROL BOARD
(2)
RH HARVEST
(6)
(60)
SOLENOID
(5)
(1)
(7)
(57)
(4)
(98)
TRANS.
FUSE (7A)
(58)
(59)
CLEAN
AIR
L2
LEFT BIN
PUMP
RIGHT BIN
(56)
RMT BIN
AIR
WTR PROBE
(26)
PUMP
ICE PROBE
WHEN USED
HARVEST
SL-1
(25)
SL-2
(9)
(8)
BIN
SWITCH
(6)
LOW D.C.
VOLTAGE
PLUG
CLEAN
(1)
OFF
ICE
(2)
(RED)
RUN
COMPRESSOR
CAPACITOR
R
(YELLOW)
S
R
(46)
C
PTCR
(45)
(86)
(44)
FAN MOTOR
(AIR COOLED ONLY)
FAN CYCLE
CONTROL
RUN CAPACITOR**
WATER
VALVE
L2 OR N
(22)
LH HARVEST
SOLENOID
(87)
(88)
(99)
(80)
(76)
(81)
DUMP
SOLENOID
WATER
PUMP
TERMINATES AT
PIN CONNECTION
CONTACTOR
COIL
(75)
(74)
(50)
R
275