28 Introduction to the manual

Terms and abbreviations

Term/
Explanation
Abbreviation
BCU
Drive control unit. The drive contains two BCU control units. One controls the supply unit,
the other controls the inverter unit.
As standard, the external I/O control signals are connected to the control unit, or optional I/O
extensions mounted on it.
Drive
Frequency converter for controlling AC motors. The drive consists of the
line-side converter) and the
the DC link.
In this manual, the term refers to the ACS880-37 as a whole.
EMC
Electromagnetic compatibility
EMI
Electromagnetic interference
EMT
Electrical metallic tubing
FAIO-01
Optional analog I/O extension module
FCAN-01
Optional FCAN-01 CANopen adapter module
FCNA-01
Optional ControlNet™ adapter module
FDCO-01
Optional DDCS communication module with two pairs of 10 Mbit/s DDCS channels
FDNA-01
Optional DeviceNet™ adapter module
FECA-01
Optional EtherCAT adapter module
FEN-01
Optional TTL incremental encoder interface module
FEN-11
Optional TTL absolute encoder interface module
FEN-21
Optional resolver interface module
FEN-31
Optional HTL incremental encoder interface module
FENA-11
Optional Ethernet adapter module for EtherNet/IP™, Modbus TCP and PROFINET IO
protocols
FENA-21
Optional Ethernet adapter module for EtherNet/IP™, Modbus TCP and PROFINET IO
protocols, 2-port
FEPL-01
Optional Ethernet POWERLINK adapter module
FIO-01
Optional digital I/O extension module
FIO-11
Optional analog I/O extension module
FLON-01
Optional LonWorks® adapter module
FPBA-01
Optional PROFIBUS DP adapter module
Frame (size)
Relates to the construction type of the component in question. For example, several drive
types with different power ratings may have the same basic construction, and a frame size is
used in reference to all those drive types.
The frame size marking of the drive indicates the quantity and frame size of the supply
modules, plus the quantity and frame size of the inverter modules, eg. "2×R8i + 2×R8i".
To determine the frame size of a drive type, see the rating tables in chapter
FSO-12
Optional functional safety module
IGBT
Insulated gate bipolar transistor; a voltage-controlled semiconductor type widely used in
drives due to their easy controllability and high switching frequency.
Inverter unit
The part of the
modules and their auxiliary components.
The inverter unit is also capable of feeding energy from a decelerating motor into the DC
link.
I/O
Input/Output
Power module Supply module or inverter module. See also
RFI
Radio-frequency interference
SAR
Safe acceleration range
inverter unit
drive
that converts DC to AC for the motor. Consists of one or more inverter
(aka motor-side converter) connected together by
Frame
(size).
supply unit
(aka
Technical
data.

Hide quick links: