STO response time: 2 ms (typical), 25 ms (maximum)
Fault detection time: Channels in different states for longer than 200 ms
Fault reaction time: Fault detection time + 10 ms
STO fault indication (parameter 31.22) delay: < 500 ms
STO warning indication (parameter 31.22) delay: < 1000 ms

Abbreviations

Abbr.
Reference
Cat.
EN ISO 13849-1
CCF
EN ISO 13849-1
DC
EN ISO 13849-1
FIT
IEC 61508
HFT
IEC 61508
MTTF
EN ISO 13849-1
d
PFD
IEC 61508
PFH
IEC 61508
D
PL
EN ISO 13849-1
SC
IEC 61508
SFF
IEC 61508
SIL
IEC 61508
SILCL
IEC/EN 62061
SS1
IEC/EN 61800-5-2
STO
IEC/EN 61800-5-2
T1
IEC 61508
Declaration of conformity
See section
Compliance with the European Machinery Directive
Description
Classification of the safety-related parts of a control system in respect
of their resistance to faults and their subsequent behavior in the fault
condition, and which is achieved by the structural arrangement of the
parts, fault detection and/or by their reliability. The categories are: B, 1,
2, 3 and 4.
Common cause failure (%)
Diagnostic coverage
Failure in time: 1E-9 hours
Hardware fault tolerance
Mean time to dangerous failure: (The total number of life units) / (the
number of dangerous, undetected failures) during a particular
measurement interval under stated conditions
Probability of failure on demand
Probability of dangerous failures per hour
Performance level. Levels a...e correspond to SIL
Systematic capability
Safe failure fraction (%)
Safety integrity level (1...3)
Maximum SIL (level 1...3) that can be claimed for a safety function or
subsystem
Safe stop 1
Safe torque off
Proof test interval. See also section
The Safe torque off function 233
Maintenance
(page 231).
(page 184).