Jumper Functions - Kemppi MasterTig AC/DC 2000 Service Manual

Hide thumbs Also See for MasterTig AC/DC 2000:
Table of Contents

Advertisement

Jumper functions

Jumper
J01
Upslope angle is constant, time is dependant
Upslope
on the set value.
J02
Downslope angle is constanttime is
Downslope
dependant on the set value.
J03
TIG antifreeze is on.
TIG antifreeze
J04
Manual AC balance adjustment.
AC balance
J05
Tacking automatics is disabled.
Tacking automatics
J06
The downslope drops to minimum current
Downslope cut-off
(3A DC, 10A AC).
level
J07
OCV is 39V. (22V/VRD)
OCV
J08
In the ending of the 4T function the
"china logic"
downslope is started by pressing the torch
switch. The downslope is on while the
switch is pressed, welding current is cut-off
when the switch is released. If it is pressed
for a longer time than the downslope, then
the current remains on the end current level
(see J06).
J09
Inverter frequency is 18 kHz on the whole
Inverter frequency
current level.
J10
Hot/soft–start is in use wit TIG 2T-function.
2T hot/soft-start
J11
Hot/soft–start time with 2T-function.
2T hot/soft–start
Adjustment range is 0,0- 9,9 s.
time adjustment
J12
On 2T the downslope is not cut-off by a
2T downslope
short (nor long) press on the switch.
J13
On AC-TIG the height of the pos. half-cycle
AC-welding positive
is the same as the negative half-cycle´s
half-cycle
height.
J14
Torch switch short press time limit is 0,3 s.
Start switch short
press
J15
AC-TIG-welding is started with a negative
AC-TIG start cycle
half-cycle.
J16
Length adjustment for the DC start of the
AC-TIG start cycle
positive half cycle in AC-TIG 0.0 .... 2.0.
length
J17
MMA ignition pulse height adjustment 0.0
MMA ignition pulse
..... 2.0.
J18
-
J19
-
ON
Upslope set time remains constant, not
depending on the set value.
Downslope set time remains constant, not
depending on the set value.
TIG antifreeze is not on.
Balance automatics is on.
Tacking automatics is enabled.
The downslope drops to the end level,
which is 20% of the welding current.
OCV is 70V.
Normal 4T function.
Inverter frequency is 18kHz/36kHz on
MMA.
Hot/soft–start is not in use with TIG 2T-
function.
On 2T the welding is stopped by a short
pres on the switch during the downslope.
On AC-TIG the height of the pos. half-
cycle depends on the set value and balance
adjustments.
Torch switch short press time limit is 0,7 s.
AC-TIG-welding is started with a positive
half-cycle.
Factory setting is 1.
Factory setting is 1.
-
-
OFF
11