Technical Data - Kemppi MasterTig AC/DC 2000 Service Manual

Hide thumbs Also See for MasterTig AC/DC 2000:
Table of Contents

Advertisement

Technical data

Mastertig AC/DC
Supply voltage
3~50/60 Hz
Loadability
TIG 70% ED
TIG 100% ED
MMA 40% ED
MMA 60% ED
MMA 100% ED
Fuse
230 V
400 V
460 V
W elding current range
TIG DC
TIG AC
MMA DC
MMA AC
OCV
AC frequency
Fixed/adjustable
Efficiency
Power factor
Temp class
Degree of protection
Dimensions
L, W, H (mm)
W eight
Kg
Coolant max. press.
Cooling unit power
2500 and 2500 W
230,400,460V +/-10%
250 A / 7,5 kVA
200 A / 6,7 kVA
250 A / 10,3 kVA
200 A / 7,9 kVA
20 A Slow
16 A Slow
16 A Slow
3 A / 10 V ... 250 A / 20 V
10 A / 10 V ... 250 A / 20 V
10 A / 20 V ... 250 A / 30 V
10 A / 20 V ... 220 A / 30 V
70 V DC
60 Hz / 50 ... 200 Hz
80 % ( 250 A / 30 V )
0,9 ( 250 A / 30 V )
B ( 130 C ) H ( 180 C )
IP 23 C
690 x 260 x 550, 830
39 / 65
350 kPa
1300 W
3500 W
400 V + / - 10%
350 A / 11,7 kVA
320 A / 9,3 kVA
350 A / 15,7 kVA
280 A / 11,2 kVA
20 A Slow
3 A / 10 V ... 350 A / 24 V
10 A / 10 V ... 350 A / 24 V
10 A / 20V ... 350 A / 34 V
10 A / 20V ... 350 A / 34 V
70 V DC
60 Hz / 50 ... 200 Hz
80 % ( 350 A / 34 V )
0,9 ( 350 A / 34 V )
B ( 130 C ) H ( 180 C )
IP 23 C
690 x 260 x 870
74
350 kPa
1300 W
5