14 Configuration menu

Function
To reprogram a number of parameters. See Figs. 3.1.
Procedure
1. Starting from the Main screen (see section 3.2):
-
press the key “Menu” (F1)
-
press the ¯ key until the option “Modify params” is
followed by a horizontal arrow
-
press the tabulator key (5) to activate the menu
2. Use the ¯ key to scroll until the option “Configuration” is
followed by a horizontal arrow.
3. Press the tabulator key (5): The first option shown is “Time”.
If another option is desired, scroll through the display (using
¯ or ­ keys) and select it using the tabulator key (5).
4. In case of option “Time”, the second line on the screen
indicates the actual setting, e.g. 14:30.
5. If it is desired to modify the time, press the key “Mod”. If
not, press the key “Menu” to return to the submenu.
6. After pressing the key “Mod”, the first field (14) will blink.
Modify the hours using the ¯ or ­ keys. Then press the
tabulator key (5) to go to the next field (i.e. 30). The setting
of this field can now be modified with the ¯ or ­ keys.
7. The bottom line of the display will show two options:
-
“Prog” to program the new setting
-
“Canc” to cancel the new setting
8. Proceed in a similar way for the other parameters to be
modified.
14.1 Programming compressor control
modes
Compressor control modes
The compressor can be controlled locally, remotely or via a
local area network (LAN). See the related Instruction book,
section 3.2.
Procedure
1. Starting from the Main screen (see section 3.2):
-
press the key “Menu” (F1)
-
press the ¯ key until the option “Modify params” is
followed by a horizontal arrow
-
press the tabulator key (5) to activate the menu
2. Use the ¯ key to scroll until the option “Configuration” is
followed by a horizontal arrow.
3. Press the tabulator key (5): The first option shown is “Time”.
Scroll through the display (using ¯ or ­ keys) until the option
“CCM” is followed by a horizontal arrow and select it using
the tabulator key (5). Following screen is shown:
2920 1461 03
Downloaded from
www.Manualslib.com
manuals search engine
CCM
Local control
Menu
Mod
F1
F2
Fig. 14.1
Compressor control mode menu
4. Press the key “Mod” and use ¯ or ­ keys to select the desired
control mode. Press the “Prog” key to program or the
“Cancel” key to cancel the modification.
15 Service menu
Function
-
To reset the service plans which are carried out.
-
To check for both the next service plans to be carried out
and to find which service plans were carried out previously.
Service plans
-
Consult the related Instruction book to find which service
actions are related to these plans.
-
Consult section 12 if any modification to the intervals should
be required.
When the service plan interval is reached, a message will appear
on the screen. See section 5.
Example
Programmed service plan intervals ex-factory
Service plans
Service plan A
Service plan B
Service plan C
Service plan D
Resulting service actions to be carried out
Service actions according to
Service plan A and B
Service plan A, B and C
Service plan A and B
Service plan A, B and C
­
¯
F3
Intervals
Each 4000 running hours
Each 4000 running hours
Each 8000 running hours
Each 40000 running hours
At
4000 running hours
8000 running hours
12000 running hours
16000 running hours
….