7.7 Set of parameters
Starting from the Main screen:
Press arrow key (12) until r007 is shown and press enter key
(5): the number shown indicates the set of parameters which
are programmed ex-factory.
7.8 Calling up/modifying Unloading pressure
Starting from the Main screen:
1. Press arrow key (12) until P001 is shown and press the
enter key (5):
The screen shows the setting of the unloading pressure: 7.0
bar(e).
2. Use arrow keys (12 and 13) to modify this setting.
3. Press enter key (5) to program the new value and to return
to the parameter screens.
2920 1461 03
Downloaded from
www.Manualslib.com
bar
6.6
bar
6.6
bar
7.0
manuals search engine
7.9 Calling up/modifying Loading pressure
Starting from the Main screen:
bar
6.6
1. Press arrow key (12) until P002 is shown and then press
enter key (5):
bar
6.4
The screen shows the setting of the loading pressure: 6.4 bar(e).
2. Use arrow keys (12 and 13) to modify this setting.
3. Press enter key (5) to program the new value and to return
to the parameter screens.
7.10 Calling up/modifying Dewpoint
warning temperature
Starting from the Main screen:
bar
6.6
S3
1
52236F
10 11 8
13
2
3
4
12
5
9 7
6