Xc2002™ Menu Overview - Atlas Copco XAS 400 JD IT4 HOP Instruction Manual

Ac compressor
Table of Contents

Advertisement

XC2002™ MENU OVERVIEW
At Xc2002™, the LCD will show the following
information through the display views:
1. in Normal condition (scroll through the information
using UP and DOWN):
- Controller type & version
Xc2002
1.40.0
This view shows the controller type and the software
version number.
- Fuel level
Fuel
12%
00000.h
This view shows the fuel level (in %) and the running
hours.
- Vessel pressure
Vessel
2.1bar
00000.h
This view shows the vessel pressure and the running
hours.
See also "Parameter list" on page 30 for selection between
metric (bar) or imperial (psi) units
- Engine RPM
RPM
0
00000.h
This view shows the engine running speed (in RPM) and
the running hours.
- Fuel pressure
E|C Fuel
--bar
pressure
00000.h
This view shows the fuel pressure and the running hours.
See also "Parameter list" on page 30 for selection between
metric (bar) or imperial (psi) units.
- Fuel consumption
E|C Fuel
--L/h
rate
00000.h
This view shows the engine fuel consumption and the
running hours.
See also "Parameter list" on page 30 for selection between
metric (L/h) or imperial (Gal/h) units.
- Alarm list
- contains a list of active alarms
Alarm list
0 Alarm(s)
This view shows the number of active alarms and gives
access to them.
An overview is given in "Alarm Display (pop up
window)" on page 33.
- Extra views display
Extra Views
This view shows the extra views available in the
controller.
- 29 -
- Regulating pressure
RegP
0.37bar
00000.h
This view shows the regulating pressure and the running
hours.
See also "Parameter list" on page 30 for selection between
metric (bar) or imperial (psi) units.
- Coolant temperature
Temp
0°C
00000.h
This view shows the engine coolant temperature and the
running hours.
See also "Parameter list" on page 30 for selection between
metric (°C) or imperial (°F) units.
- Oil pressure
Oil
--bar
00000.h
This view shows the engine oil pressure and the running
hours.
See also "Parameter list" on page 30 for selection between
metric (bar) or imperial (psi) units.
- Unit Type
Unit Type
1
1
This view shows the model type of the compressor.
1 = default unit type
It is possible to scroll between configuration menu's by
using the pushbuttons UP and DOWN.
10

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xats 400 jd it4 hopXavs 400 jd it4 hop

Table of Contents