Calling Up Running Hours - Atlas Copco GA5 User Manual

Stationary air compressors with elektronikon i or ii regulator
Hide thumbs Also See for GA5:
Table of Contents

Advertisement

User manual
Parameter
screens
P001
P002
P003
P004
P005
P006
P007
P008
P009
P010
7.1 Calling up outlet and dewpoint
temperatures
Starting from the Main screen:
1. Press arrow key (12), the outlet temperature will be shown:
The screen shows that the outlet temperature is 83 °C.
S3
52236F
2920 1461 03
Downloaded from
www.Manualslib.com
Used for
Unload pressure setting
Load pressure setting
Warning level setting for dewpoint temperature
Setting of service timer
Setting of unit for pressure
Setting of unit for temperature
Selection between Y-D or DOL starting
Selection for function "Automatic restart after
voltage failure" (active or not, only for Atlas
Copco)
Selection between Local/Remote control
Changing set of programmed parameters (only
for Atlas Copco)
bar
6.6
°C
83
1
2
3
10 11 8
9 7
13
manuals search engine
2. Press arrow key (12), the dewpoint temperature will be
shown:
The screen shows that the dewpoint temperature is 3 °C.
3. Use keys (12 and 13) to scroll downwards or upwards
through the screens.

7.2 Calling up running hours

Starting from the Main screen:
1. Press arrow key (12) until “r001” is shown and then press
enter key (5):
The screen shows the unit used (“kHrs” or hours x 1000) and
the value “2.381”: the running hours of the compressor are 2381
hours.
4
7.3 Calling up loading hours
Starting from the Main screen:
12
5
6
°C
3
bar
6.6
kHrs
2.381
bar
6.6
9