Procedure
1. Starting from the Main screen (see section 3.2):
-
press the key Menu (F1)
-
press the ¯ key until the option Service is followed
by a horizontal arrow
-
press the tabulator key (5) to activate the menu
2. A screen similar to the one below appears:
Service Timer
Running Hours
hrs
Menu
F1
Fig. 15.1 Service menu
The screen shows that the total compressor running time is 7971
hrs.
3. Press the tabulator key (5):
Next Timer
Level
hrs
Back
F1
Fig. 15.2 Service menu
The screen shows that the next service plans to be carried out
are plans A, B and C and that these plans are to be carried out
each 8000 running hours.
4. Press the ¯ key to find which service plans were carried out
previously:
Previous Timer
Level
hrs
F1
Fig. 15.3 Service menu
The screen shows that service plans A and B were carried out
at 4008 running hours.
5. Stop the compressor, switch off the voltage and carry out
the service operations related to plans A, B and C. See the
related Instruction book.
6. Switch on the voltage and scroll to the service screen shown
in Fig. 15.2. Press the Rset button (F3) to reset the timer.
Confirm the question for resetting.
30
Downloaded from
www.Manualslib.com
7971
F2
F3
A B C
8000
Rset
F2
F3
A B
4008
F2
F3
manuals search engine
Notes
-
The Rset button only appears when the next Timer level
is almost reached (from 400 running hours before elapsing
of the service plan interval).
-
After pressing the ¯ key in Fig. 15.1, the Life time hours
are shown (i.e. the number of hours elapsed since initial
programming ex-factory). This counter is not taken into
account.
®
¯
16 Saved data menu
Function
To call up some compressor data saved by the regulator. These
data are:
-
Last shut-down data
-
Last emergency stop data
¯
Procedure
1. Starting from the Main screen (see section 3.2):
-
press the key Menu (F1)
-
press the ¯ key until the option Saved data is followed
by a horizontal arrow
-
press the tabulator key (5) to activate the menu
2. The list of last shut-down and emergency stop cases is
shown.
3. Scroll through the items to select the desired shut-down or
emergency stop item.
4. Press the tabulator key (5) to find the date, time and other
data reflecting the status of the compressor at the last shut-
down occurred.
1
S3
52237F
9
User manual
2
3
12
6
8 11
10
7
2920 1461 03
4
5
4
9
9