Full wire speed switching
64
128
256
512
1024
1280
1518
Note
The number of SCALANCE XF-200G modules connected in a line influences the frame delay.
When a frame passes through the IE switch, this is delayed by the store-and-forward function of
the SCALANCE XF-200G by 10-130 microseconds (at 100 Mbps).
8.4

Mechanical stability (in operation)

Mechanical stability (in operation)
Device
SCALANCE XF204G
SCALANCE XF-200G
Operating Instructions, 02/2023, C79000-G8976-C676-01
148810
84459
45290
23496
11973
9615
8127
IEC 60068-2-27 shock
15 g, 11 ms duration
6 shocks per axis
Technical specifications
8.4 Mechanical stability (in operation)
1488095
844594
452898
234962
119731
96153
81274
IEC 60068-2-6 vibration
10 - 58 Hz: 0.075 mm
85 - 150 Hz: 1 g
1 octave/min, 20 sweeps