Technical specifications
Design of the mounting bracket for four-point mounting
Dimensions (W x H x D)
Plate thickness
Bending radii
Surface of the housing
Mean time between failure (MTBF)
MTBF (EN/IEC 61709; 40 °C)
Wiring rules
1)
Note the wiring rules.
Ambient temperature with SFP
2)
The maximum ambient temperature during operation depends on the operating elevation
and the installed plug-in transceivers, see also the section "SFP plug-in transceiver" in the
"Accessories" section.
Restriction when operating with plug-in transceivers of this type
3)
A maximum of two plug-in transceivers of this type may be used.
Derating
4)
The derating values depend on the maximum ambient temperatures during operation up to
2000 m.
Degree of protection
5)
The IP20 degree of protection was not examined in the context of UL certification.
See also
Wiring rules (Page 65)
Accessories (Page 36)
9.5

Mechanical stability (in operation)

The devices listed in the scope of validity meet the following requirements for mechanical
stability during operation:
IEC 60068-2-27 shock
SCALANCE XR-500
Operating Instructions, 07/2023, C79000-G8976-C692-01
43.6 x 43.6 x 18.3 mm (1 height unit)
1.5 mm
1.5 mm
Stainless steel X6CR17
6GK5534-2TR00-3AR3
6GK5534-2TR00-4AR3
15 g, 11 ms duration
6 shocks per axis
9.5 Mechanical stability (in operation)
> 8.3 years
> 10.2 years
IEC 60068-2-6 vibration
10 - 58 Hz: 0.075 mm
85 - 150 Hz: 1 g
1 octave/min, 20 sweeps
Technical specifications
115