Download Print this page
CAME ZLJ24 Installation Manual

CAME ZLJ24 Installation Manual

For 24 v gearmotors
Hide thumbs Also See for ZLJ24:

Advertisement

CONTROL PANEL
FOR 24 V GEARMOTORS
FA 00038 -E N
INSTALLATION MANUAL
ZLJ24
EN
English

Advertisement

loading

Summary of Contents for CAME ZLJ24

  • Page 1 CONTROL PANEL FOR 24 V GEARMOTORS FA 00038 -E N INSTALLATION MANUAL ZLJ24 English...
  • Page 2 All connections are quick-fuse protected. Intended use Control panel Gearmotor ZLJ24 AMICO - AXO - F4000 - FAST - FERNI - FROG - FROG J - MYTO Any installation and/or use other than that specified in this manual is forbidden. Technical data...
  • Page 3 Description of parts 1. Transformer 2. Power supply on warning LED 3. Display 4. Programming buttons 5. Display brightness adjusting trimmer 6. Programming warning LED 7. Memory roll board connector 8. Connector for the R700 card 9. AF card connector 230V 230V 10.
  • Page 4 Cable types and minimum thicknesses Cable length Cable length Cable length Connection Cable type 1 < 10 m 10 < 20 m 20 < 30 m Control panel power-supply 2 x 1.5 mm 2 x 1.5 mm 2 x 2.5 mm Encoder gearmotor power supply* 3 x 1.5 mm 3 x 1.5 mm...
  • Page 5 ELECTRICAL CONNECTIONS Power supply to accessories Possible output of the second radio-receiver Terminal board for 24 V AC Electric lock connection at 12 V - channel (NO contact). / DC accessories - Maximum power: 50 W Maximum power: 15 W Contact rated for: 500 mA - 24 V DC.
  • Page 6 Command and control devices Before fitting any snap-in cards (such as the AF or R700), YOU MUST CUT OFF MAINS POWER, and , if present, disconnect the batteries.  Fit the AF card to control the operator via transmitter. Transponder or card reader Black ...
  • Page 7 Warning devices Gate open warning light (Contact rated for: 24 V - 3 W max). Flashing light (contact rated for: 24 V - 25 W max). Flashes when the To warn that the gate is open. gate is opening and closing. It switches off when the gate is closed.
  • Page 8 10 11 TS E ES 1 2 3 3P 4 5 7 CX CY CZ 10 11 TS E ES 1 2 3 3P 4 5 7 CX CY CZ Connection with Came Remote Protocol (CRP) S1 GND B1 B2...
  • Page 9 PROGRAMMING Description of programming commands the <-----> signs on the display are for: - showing the currently selected item The ESC button is for: The ENTER key is for: - exiting menus; - entering menus; - cancelling changes. - confirming or memorizing set values. The <...
  • Page 10 Meaning of the menu items abbreviations [Run Amperom] Gate Run Sensitivity [Ped. opening] Partial Opening [Maintained Act] Maintained Action [Autoclose] Automatic Closing [Config] Configuration [Related Func.] Related Function [Imp.Run] Set gate run [M1 Appr. AP %] M1 Opening approach as a percentage [M1 Appr.
  • Page 11 [ENCODER] Default [Sensibility] [Turn on] / [Disabled] [Turn on] ◦+] [Sensib. Run] [Sensib. Decel] ◦+] [Slow run Enc] [ON] / [OFF] [ON] [1%] ⇨ [60%] [M1 Slow.AP %] [10%] [M1 Slow.CH %] [1%] ⇨ [60%] [10%] [M2 Slow.AP %] [1%] ⇨ [60%] [10%] [1%] ⇨...
  • Page 12 [Obstacle Det] [Disabled] / [Turn on] With the gate leaves are closed, open or after a total stop, the operator stays idle if the safety devices (photocells and sensitive safety-edges) detect an obstruction. [Safety Test] [Disabled] / [CX] / [CY] / [CZ] / [CX+CY] / [CX+CZ] / [CY+CZ] / [CX+CY+CZ] After every opening or closing command, the board will check whether the photocells are working properly [Prefl...
  • Page 13 [1] ⇨ [32] [CRP address] With systems fitted with several operators and the CRP (Came Remote Protocol) system connection, set an address between 1 and 32 for each control panel. [CRP baudrate] [1200] / [2400] / [4800] / [9600] / [19200] / [38400] / [57600] / [115200] Setting the communication speed used in the CRP (Came Remote Protocol) connection system.
  • Page 14 [1%] ⇨ [60%] [M1 Slow.AP %] Adjusting the M1 slowdown starting point before the opening endstop. The slowdown starting point is calculated as a percentage (from 1% to 60% of the complete gate leaf run).  This function only appears if the [Slow run Enc] function is selected in the [ENCODER] menu. [1%] ⇨...
  • Page 15 [Ped.opening] [5 s] ⇨ [60 s] M2 opening time. The time can be adjusted to between fi ve seconds and 60 seconds. Users Menu [USERS] [Add User] Entering up to 250 users and associating a function from those available with each one. The entering must be done via transmitter or other control device (see paragraph on ENTERING NEW USERS).
  • Page 16 Entering a new user 1. From the 2. Select [confirm [USERS] menu, < Add User > Add User (yes)] and press ENTER select the [Add <Confirm?(yes)> to confirm. User] function. Press ENTER to confirm. 3. Select the function 4..a code to enter will Assoc Function to associate to users.
  • Page 17 Modify code 1. From the 2. Select the user name [USERS] menu, < Change Code > Change Code whose code you want select [Change to modify and press Change Code Code]. Press ENTER to confirm. ENTER to confirm < 002: --U002-- > 3.
  • Page 18 Travel calibration Before calibrating the gate run, check that the maneuvering area is free from any obstruction and that there are both opening and closing mechanical stops. The mechanical end-stops are obligatory. Important! During the calibration, all safety devices will be disabled except for the PARTIAL STOP one. 1.
  • Page 19 DIAGRAM OF THE SLOWDOWN AND FINAL APPROACH POINTS AND FOR THE ENCODER DEVICE  The run area and slowdown and approach points are tested according to the parameters set forth by Technical Standards EN 12455 and EN 12453 for compliance with the impact forces generated by the running leaves. = Normal speed B* = Slowed-down speed = Encoder intervention zone with movement inversion...
  • Page 20 Came S.p.A. Came S.p.A. Via Martiri Della Libertà, 15 Via Cornia, 1/b - 1/c 31030 Dosson di Casier Dosson di Casier 33079 Sesto al Reghena Sesto al Reghena Treviso Treviso - Italy Pordenone Pordenone - Italy (+39) 0422 4940 (+39) 0434 698111...