5 PROGRAMMING

5.2 When Remote Net Ver. 1 Mode Is Used

5.2.1 Conditions of Program Example
The program examples in this section are created under the following conditions.
(1) System configuration
(2) Relationships between PLC CPU, master module and
PLC CPU
Device X
X400 to X40F
X410 to X41F
Device Y
Y400 to Y40F
Y410 to Y41F
Device D
D200
D201
D202
D203
D204
D205
D206
D207
D208
D209
D210
D211
Device D
D300
D301
D302
D303
D304
D305
D306
D307
D308
D309
D310
D311
In the program example (refer to Section 5.2.4) that uses the RRPA instruction (automatic refresh
parameter setting) with the ACPU/QCPU (A mode), RWr0 to RWr8 are assigned to D456 to D464.
5 - 2
PLC CPU
Master station
(X0 to X1F/Y0 to Y1F)
I/O (Input 64 points)
(X20 to X5F)
I/O (Output 64 points)
(Y60 to Y9F)
AJ65VBTCU-68ADVN
Master module
Address
Remote input (RX)
E0
RX00 to RX0F
H
E1
RX10 to RX1F
H
Remote output (RY)
160
RY00 to RY0F
H
161
RY10 to RY1F
H
Remote register (RWw)
1E0
RWw0
H
1E1
H
1E2
RWw2
H
1E3
RWw3
H
1E4
RWw4
H
1E5
H
1E6
RWw6
H
1E7
RWw7
H
1E8
RWw8
H
1E9
H
1EA
RWwA
H
1EB
RWwB
H
Remote register (RWr)
2E0
H
2E1
H
2E2
H
2E3
H
2E4
H
2E5
H
2E6
H
2E7
H
2E8
H
2E9
H
2EA
H
2EB
H
AJ65VBTCU-68ADVN
(Station number 1)
AJ65VBTCU-68ADVN
(Station number 1)
Remote input (RX)
RX00 to RX0F
RX10 to RX1F
Remote output (RY)
RY00 to RY0F
RY10 to RY1F
Remote register (RWw)
RWw0 A/Dconversion/prohibit
specification
RWw1 CH.1 to CH.4 input range
RWw1
setting
RWw2 CH.5 to CH.8 input range
setting
RWw3 Average processing
spacification
RWw4 CH.1 average time,
number of times setting
RWw5 CH.2 average time,
RWw5
number of times setting
RWw6 CH.3 average time,
number of times setting
RWw7 CH.4 average time,
number of times setting
RWw8 CH.5 average time,
number of times setting
RWw9 CH.6 average time,
RWw9
number of times setting
RWwA CH.7 average time,
number of times setting
RWwB CH.8 average time,
number of times setting
Remote register(RWr)
RWr0
RWr0 CH.1 difital output value
RWr1
RWr1 CH.2 digital output value
RWr2
RWr2 CH.3 digital output value
RWr3
RWr3 CH.4 digital output value
RWr4
RWr4 CH.5 digital output value
RWr5
RWr5 CH.6 digital output value
RWr6
RWr6 CH.7 digital output value
RWr7
RWr7 CH.8 digital output value
RWr8
RWr8 Error code
RWr9
RWr9 Reserved
RWrA
RWrA Reserved
RWrB
RWrB Reserved
MELSEC-A
5
5 - 2