Siemens SIWAREX FTA Device Manual page 89

Weighing electronics for automatic scale
Table of Contents

Advertisement

Name
Type
Level definition for digital
BYTE
outputs 1....8
Replacement values for
BYTE
digital outputs 1 .... 8
upon fault or OD signal
Activate - Digital output
BYTE
replacement values for
operational faults
Reserve 3
BYTE
Digital inputs
Definition of digital input 1 BYTE
Definition of digital input 2 BYTE
Definition of digital input 3 BYTE
Definition of digital input 4 BYTE
Definition of digital input 5 BYTE
Definition of digital input 6 BYTE
Definition of digital input 7 BYTE
Level definition for digital
BYTE
inputs 1...7
Measurement time for
TIME
pulse input
Reserve 4
DWORD
MMC Parameter
Log overflow
BYTE
SIWAREX FTA
Address
Default
Range of Values / Explanation
FDh
FEh
FFh
Range of values 40h – FCh not permitted
DBB056
0
Bit 0 : DA1 -> 0 = high active: 1 = low active
....
Bit 7 : DA8 -> 0 = high active: 1 = low active
DBB057
0
Bit 0 : Replace value digital output 1
....
Bit 7 : Replace value digital output 8
DBB058
0
Bit 0 :
0: Replacement output upon operating error
deactivated
1: Replacement output upon operating error
activated
Bit 1 - 7 not used
DBB059
0
Reserve 3
0
DBB060
0
0 = No command
1- 254 = Command code
255 = Step-on condition. (see DR -7 Scale
parameter/Step control
DBB061
0
0 = No command
1- 254 = Command code
255 = Step-on condition. (see DR - Scale
parameter/Step control)
DBB062
0
0 = No command
1- 254 = Command code
255 = Step-on condition. (see DR - Scale
parameter/Step control)
DBB063
0
0 = No command
1- 254 = Command code
255 = Step-on condition. (see DR - Scale
parameter/Step control)
DBB064
0
0 = No command
1- 254 = Command code
255 = Step-on condition. (see DR - Scale
parameter/Step control)
DBB065
0
0 = No command
1- 254 = Command code
255 = Step-on condition. (see DR - Scale
parameter/Step control)
DBB066
0
0 = No command
1- 254 = Command code
255 = Step-on condition. (see DR - Scale
parameter/Step control)
DBB067
0
Bit 0 : Digital input 1 -> 0 = high active: 1 = low
active
....
Bit 6 : Digital input 7 -> 0 = high active: 1 = low
active
Bit 7 : not used.
DBB068
1 sec
100 to 10000 ms
Other definitions not permitted.
DBB072
0
Reserve 4
0
DBB076
3
Bit 0 :
0: with full memory, the logging procedures are
stopped
1: with full memory, the oldest entries are
Weighing Functions
Start cycl. transfer DigLC
Stop cycl. transfer DigLC
Output always inactive
5.16.16
)
Reference
5.6.20
5.6.21
5.6.22
5.6.23
5.6.23
5.6.23
5.6.23
5.6.23
5.6.23
5.6.23
5.6.24
5.6.25
5.6.26
5-77

Advertisement

Table of Contents
loading

Table of Contents