Weighing Functions
Name
Definition check stop
BYTE
Reserve 5
BYTE
Post dosing tolerance
check
BYTE
Automatic dosing
Dosing method
Stop if more than TO1
Stop if more than TO2
Stop for more than TU1
Stop for more than TU2
Continue after TOL-Stop
Control pause
BYTE
Pulse duration for pulse
TIME
dosing
Controller
Controller behaviour at
BYTE
scale fault
5-98
Type
Address
Default
DBB052
0
DBB053
0
DBB054
0
DBB055
0
DBD056
1000 msec
DBB060
0
Range of Values / Explanation
Bit 0 : No check stop
Bit 1 : Weighing goes to check stop after step 1
Bit 2 : Weighing goes to check stop after step 2
...
Bit 7 : Weighing goes to check stop after step 7
Other definitions not permitted.
Reserve 5
Bit 0 :
0: No automatic post dosing
1: autom. post dosing for Tol-1 deviation
Bit 1 :
0: post dosing with continuous
fine signal
1: post dosing pulse mode
Bit 2 :
0: Weighing procedures not stopped
because of tolerance errors
1: Weighing stopped because of tolerance error
(weight above TO1)
Bit 3 :
0: autom. Weighing procedures not stopped
because of tolerance errors
1: Weighing stopped because of tolerance error
(weight above TO2)
Bit 4:
0: Weighing procedures are not stopped because
of tolerance errors
1: Weighing procedure is stopped because of
tolerance error (weight under TU1)
Bit 5:
0: autom. weighing procedures are not stopped
because of tolerance errors
1: Weighing procedure is stopped after a filling
procedure because of a tolerance error (weight
under TU2)
Bit 6:
0: Cycle cannot be continued when the TOL error
persists
1: Cycle can be continued even though the TOL
error exists
Bit 7 not used
0: All weighing procedures are checked for
tolerance deviations
1: A weighing procedure is not checked for
tolerance deviations
2...98: 2...98 weighing procedures are not
checked for tolerance deviations, 99 no check
Other definitions not permitted.
Pulse duration of fine signal (in msec)
Bit 0 :
0: Reset controller for technology error
(weighing fault)
1: Limit controller to max. Access
Reference
5.16.18
5.16.19
5.16.20
5.16.21
5.16.22
5.16.23
5.16.24
5.16.25
5.16.26
5.16.27
5.16.28
SIWAREX FTA