Weighing Functions

5.5.16 DR 4 - Shut-off weight limit value 1

See: Switch-on weight limit value 1
5.5.17 DR 4 - Switch-on weight limit value 2
See: Switch-on weight limit value 1
5.5.18 DR 4 - Shut-off weight limit value 2
See: Switch-on weight limit value 1
5.5.19 DR 4 - Switch-on weight limit value 3
Switch-on and shut-off weights can be defined separately for a limit value. With
limit value 3, only the maximum weight monitor can be used The base weight for
limit value 3 is always the gross weight.
5.5.20 DR 4 - Shut-off weight limit value 3
If the value is below the limit value, the status information is reset to "limit value 3".
5.5.21 DR 4 - Minimum through-put limit value 1
The through-put measurement is performed continuously. As soon as the
determined through-put value falls below the limit value, it is indicated in the status
display.
5.5.22 DR 4 - Minimum through-put limit value 2
The through-put measurement is performed continuously. As soon as the
determined through-put value falls below the limit value, it is indicated in the status
display.
5.5.23 DR 4 - Filter depth of averaging filter for through-put calculation
A separate average value filter is used for the through-put measurement. The
through-put value is generated from the average value of the through-put value
which SIWAREX FTA calculates with a measurement rate of 10 msec.
5.6 DR 7 Interfaces (NAWI, AWI)
The parameters that define the behaviour of the SIWAREX FT on the interfaces
are defined in DR7. If an interface is not used the default values can be left alone.
o
Change parameters if required.
o
Send DR 7 to the scale
5-72
SIWAREX FTA