5.9 DR 15 Tare entry (NAWI, AWI)
DR 15 is used for an external tare weight definition.
Procedure:
o
Enter tare weight
o
Send DR 15 to the scale
o
Activate the "Accept tare entry (24)" command
Name
Tare entry
Tare entry
Table 5-8
DR 15 Allocation
5.9.1
DR 15 - Tare Entry
DR 15 is used for an external tare weight definition. After the entry with the DR 15,
the tare value is not yet activated. The transfer to the tare memory of the
SIWAREX FTA is then made with the "Accept tare entry" command (see command
code 24)
5.10 DR 16 Weight Simulation Entry (NAWI, AWI)
If the DR 16 has been defined as the source for the weight simulation (see
DR 7
Source for the weight
SIWAREX FTA is deactivated by defining a weight value with the DR 16 and the
defined value is "simulated" as a weight value.
Procedure:
o
Check for whether DR 16 has been defined as the source for the weight
simulation in DR 7
o
Enter a value to be simulated
o
Send DR 16 to the scale
Name
Simulation
Weight simulation entry
Table 5-9
DR 16 Allocation
SIWAREX FTA
Type
Address
Default
REAL
DBD000
0
4
simulation) then the measurement input of the
Type
Address
Default
REAL
DBD000
0
4
Range of Values / Explanation
External tare entry (Preset Tare).
Range of Values / Explanation
Default value for weight simulation (is used
instead of the gross weight e.g. for test)
Weighing Functions
Refe-
rence
5.9.1
Reference
5.10.1
5-89