Dr 23 - Tare / Zero Setting Cycle - Siemens SIWAREX FTA Device Manual

Weighing electronics for automatic scale
Table of Contents

Advertisement

Weighing Functions

5.16.12 DR 23 - Tare / Zero setting cycle

The entry defined how often the scale must perform a taring or zero setting:
o
0: Every weighing is nullified or tared
o
1: Tipping is not nullified or tared
o
2 to 99: 2 to 99 tippings not nullified or tared
Note
In calibrating applications with the SIWAREX FTA as an automatic weighing
instrument for emptying operation, a taring or zero setting is performed
automatically after the defined time of 15 minutes has elapsed (see DR 3
Regulations).
5.16.13 DR 23 - Tare minimum weight
Along with the parameter tare max. weight, a weighing range can be defined within
which taring is permitted.
5.16.14 DR 23 - Tare max. weight
Along with the parameter tare min. weight, a weighing range can be defined within
which taring is permitted.
5.16.15 DR 23 - Time period for zero setting
With a definition of "0", the time controlled zero setting for the scale is not
performed. A definition unequal to "0" means that the scale performs a zero setting
automatically after this time has elapsed.
Note
The time controlled zero setting is not performed in the scale cycle.
In calibrating applications with the SIWAREX FTA as an automatic weighing
instrument for emptying operation, a taring or zero setting is performed
automatically after the defined time of 15 minutes has elapsed (see DR 3
Regulations).
5-102
SIWAREX FTA

Advertisement

Table of Contents
loading