Level Sensor; Testing The Level Sensor - Upright X26 Ultra Narrow Service Manual

Scissor lift
Hide thumbs Also See for X26 Ultra Narrow:
Table of Contents

Advertisement

L
S
E V E L
W A R N I N G
!
Never perform service while the platform is elevated without first blocking the elevating assembly.
DO NOT stand in the elevating assembly area while deploying or storing the brace.
The Level Sensor Is located on the chassis between the scissor sections and is covered with a protective
metal box. To verify the sensor is working properly there are two LED's under the sensor; green indicates
the sensor is ON (has power), red indicates the sensor is LEVEL.
T
ESTING THE
1. Place machine on firm level surface.
2. Use the Chassis Controls to raise the platform to
approximately 2,1 m (7 ft.).
3. Install the scissor brace (see "Blocking The Elevating
Assembly" on page 12).
4. Remove the Level Sensor electrical box cover near the
front of machine.
5. Push the Level Sensor off of level.
6. The alarm should sound, and the red LED should turn
OFF.
• If the alarm does not sound, take the machine out of
service until the Level Sensor has been adjusted or
repaired.
7. Replace the Level Sensor electrical box cover.
8. Store the scissor brace and lower the Platform.
114100-000R1 X26 Ultra Narrow - Operator Manual
E N S O R
L
S
EVEL
ENSOR
!
Maintenance
Figure 10: Level Sensor
Page 13

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

X20nX26nX26unX31nX20wX32n

Table of Contents