cleaning the printer
The OPC drum unit is light sensitive.
Install it within five minutes.
If the OPC drum can not be installed
within five minutes, place the drum in
the original packaging to prevent light
damage.
When removing the drum unit, do not
touch the surface of the drum unit.
Fingerprints and scratches can damage
the drum surface and cause poor print
quality. Do not rotate the drum unit
manually. Forced rotation will cause an
incorrect count for the life of the drum
unit and may cause poor print quality.
6
Remove any paper from the printer.
7
Remove the OPC drum unit from
the printer by lifting up and out. Set
the unit aside.
8
Slide the corona cleaning brush
along the length of the transfer
corona wire to remove any dust or
debris.
9
Place the OPC drum unit into the
printer.
1
Replace the corona cleaning brush
in its holder on top of the OPC drum
unit.
11
Reload the paper. Refer to the
"Loading Paper" section.
12
Close the top cover of the printer
and wait for the printer to warm up.